Proflame (SIT DFC): fan, AUX outlet, split flow or OFF command not working

What is going on

Proflame GT system with Fan Control Module: fan or AUX outlet not responding, split-flow burner not switching, or the fireplace will not shut off from the remote.

Likely causes

  • Transmitter not a GTMF/GTMFS model
  • FCM not powered or switched on
  • Fan/AUX device plugged into the wrong outlet or failed
  • Pilot or DFC ground not connected to the chassis
  • Failed FCM or split flow valve
  • Remote not communicating
  • Valve stuck open

Check in this order

  1. Fan the transmitter must be a GTMF or GTMFS. Make sure the FCM is on AC power and switched on, and the fan is in the FCM outlet marked FAN. Plug the fan straight into 120 V: works = replace the FCM; does not work = replace the fan.
  2. Fan speed not following the remote check the pilot ground wire to the chassis, then replace the FCM.
  3. AUX FCM powered, device plugged in, DFC grounded to the chassis. Plug the device into 120 V directly: works = replace the FCM.
  4. Split flow transmitter must have the split flow feature; check wiring, then replace the split flow valve.
  5. Receiver not responding new receiver batteries; if it does not beep, replace the receiver. New transmitter batteries; if pressing ON/OFF does not make the receiver beep, move closer, resync, or use the correct transmitter type.
  6. Burner will not turn OFF check communication, then unplug EV1 and EV2 at the valve. If the burner still burns, shut off the gas and replace the valve. Pilot staying on is normal in CPI mode; in IPI it should go out - otherwise unplug EV1 and if it still burns, replace the valve.

Applies to: Fireplaces using the SIT Proflame GT / GTMF system

More gas fireplace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: SIT Proflame System Troubleshooting Guide (DFC / 880-885-886 valve / GT remote), fan, AUX, receiver and OFF command flow charts. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.