Majestic · Gas fireplace troubleshooting

Signature Command: pilot lit but main burner will not light

DVBL7 Signature Command

What is going on

Pilot is established and the main burner does not open.

Likely causes

  • Sensor on the pilot not in the flame, so the control never proves it.

Check in this order

  1. Adjust the sensor position in the flame
  2. Replace the pilot assembly if the sensor cannot be positioned

Applies to: 300DVBLN/PSC7, 400DVBLN/PSC7, 500DVBLN/PSC7 (Signature Command)

More gas fireplace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Majestic DVBL7 Series Installation and Operating Instructions, p. 48. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.