Majestic · Gas fireplace troubleshooting
Signature Command: no spark or no valve click after ON
What is going on
After the ready beep and pressing ON, nothing happens at the pilot.
Likely causes
- Pilot connections loose
- NG/LP conversion cap missing
- Control board interference from nearby metal (poor ground)
- Valve connections loose
Check in this order
- Check the pilot connections
- Check the conversion cap and control board connections
- Check the valve connections
- Check grounding; reseat or move the control board, replace if needed
Applies to: 300DVBLN/PSC7, 400DVBLN/PSC7, 500DVBLN/PSC7 (Signature Command)
More gas fireplace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Majestic DVBL7 Series Installation and Operating Instructions, p. 48. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.