Majestic · Gas fireplace troubleshooting
Signature Command: no beep after master switch ON
What is going on
System does not beep within about 8 seconds.
Likely causes
- Batteries wrong way round or weak
- AC plug not in the mains
- 5-pin connector on the AC board broken or bent
- Command center to control board cable not connected
- Failed AC board, control board or command center
Check in this order
- Reinstall or replace the batteries
- Plug the adapter into the mains and check for solid green LED
- Repair or replace the AC board
- Check the 2 ft / 15 ft cable at both ends
- Replace the control board or command center
Applies to: 300DVBLN/PSC7, 400DVBLN/PSC7, 500DVBLN/PSC7 (Signature Command)
More gas fireplace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Majestic DVBL7 Series Installation and Operating Instructions, p. 48. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.