Napoleon · Gas fireplace troubleshooting

Remote control: pairing / code setting and multiple remotes

What is going on

How to code the hand-held to the receiver; receiver gives a single (possibly faint) beep when it learns the code.

Likely causes

  • Code not learned
  • Interference from another remote within 50 ft

Check in this order

  1. Set the code switch on the transmitter before installing batteries.
  2. Put the receiver in 'remote' position.
  3. Install batteries; while the transmitter LCD blinks, press any button standing about five feet from the unit.
  4. Listen for one beep from the receiver (may be faint inside the fireplace); repeat if no beep.
  5. Multiple units within 50 ft: program one at a time, turn the others off, use a different code switch combination on each, and stand twenty feet from other running remotes.
  6. Receiver keeps the code through power outages and battery changes.

Applies to: Napoleon fireplaces with Wolf Steel approved remotes (service manual)

More gas fireplace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 4 Other Issues, Remote Control Guide, p.30. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.