Napoleon · Gas fireplace troubleshooting
Pilot goes out while standing (main burner OFF)
What is going on
Confirm the gas is shut off at the appliance and the pilot area is clear before you start poking around, and plan on a gas pressure test with a manometer. With the main burner off, the pilot on this Napoleon GD70 STARfire keeps going out, or flutters when another appliance or the main burner fires. That pattern points to a supply that can't keep up, usually undersized gas piping to the fireplace. A pilot that drops out all by itself with nothing else running needs a different look. Gas supply work is for a licensed technician.
Likely causes
- Gas supply piping undersized for the total connected load
- Supply pressure dropping when other appliances start
- Regulator or line restriction upstream of the fireplace
Check in this order
- Turn on all gas appliances in the house and watch the pilot, fluttering, shrinking or going out (especially when the main burner lights) points to supply starvation
- Monitor the appliance supply working pressure while everything runs (spec NG 7" w.c. min 4.5"; propane 13" w.c. min 11")
- Note the pressure with only the pilot lit, then with all appliances at full fire, and compare the two readings
- Check supply pipe sizing against code and correct any undersized piping
- Look for a kinked flex connector or partly closed shutoff upstream
- Have a licensed gas fitter do any piping or regulator changes
Applies to: Napoleon GD70 STARfire direct-vent fireplace (GD70NT-S natural gas, GD70PT-S propane)
More gas fireplace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Napoleon GD70NT-S / GD70PT-S Installation & Operating Instructions W415-0434, Troubleshooting table, p.26. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.