Napoleon · Gas fireplace troubleshooting
Pilot drops out during operation - vent-free
What is going on
Vent-free fireplaces rely on the oxygen depletion sensor (ODS) pilot, so a pilot that fails while the unit is running may just be doing its job. The ODS is built to shut the unit down when it senses low oxygen in the room. That makes room size and air supply as important as the electrical readings. Check the cheap items (pilot flame, ODS opening) first, then go on to pressure and millivolt tests.
Likely causes
- Wrong pilot flame, size or position
- Pressure drop when the burner lights
- Low thermocouple output
- Weak magnet coil
- Inlet pressure too high or too low
- Dirty ODS air opening, because dust changes the pilot flame
- Room too small (not enough unconfined space)
- Logs out of place
Check in this order
- Check pilot flame pattern, size and position, because the ODS reads the flame itself
- Check for pressure drop when the burner is activated
- Test thermocouple millivolts and the magnet coil, compare to the manual spec
- Test inline pressure, since too high pushes the pilot past the thermopile and too low prevents lighting
- Clean dirt and debris from the ODS primary air opening
- Warning: confirm the room meets the unit's minimum unconfined-space requirement, and add make-up air if not
- Check log positions
- Do not replace or alter the ODS pilot assembly, use the correct part from the manufacturer
Applies to: Napoleon vent-free gas fireplaces with ODS pilot (general service manual flowchart)
More gas fireplace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 1-3 Troubleshooting, Pilot Failure Flowchart, p.21. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.