Majestic · Gas fireplace troubleshooting

Pilot and main burner go out while running

DVBL7

What is going on

Fireplace shuts down by itself during operation.

Likely causes

  • Inner vent pipe leaking exhaust back into the system
  • Horizontal vent pitched wrongly
  • Vent cap installed wrongly or blocked

Check in this order

  1. Look for a flue leak and replace the bad pipe section
  2. Horizontal pipe must rise 1/4 in. per foot; never level or downward
  3. Check the vent cap installation and clear any debris

Applies to: DVBL7 series

More gas fireplace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Majestic DVBL7 Series Installation and Operating Instructions, p. 47. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.