Napoleon · Gas fireplace troubleshooting

Main burner low flame

What is going on

Main burner comes on but the flame is smaller than it ought to be, on a Napoleon direct-vent, natural-vent or vent-free unit. Honestly, before you start measuring, look at the simple stuff. A hi-lo knob left on low is surprisingly common, and so is a modulating remote that lost its batteries or power, because those default to low flame. If those check out, you're into gas pressure and burner parts. It's easy to think it's a gas problem when it isn't.

Likely causes

  • Modulating remote without power (defaults to low)
  • Hi-lo knob turned low
  • Low inlet or outlet pressure
  • Wrong or blocked orifice
  • Venturi misadjusted
  • Blocked manifold tube

Check in this order

  1. If there is a modulating remote, check it has power, without power it defaults to low flame
  2. Turn the hi-lo knob to high
  3. Test inlet and outlet pressures against the manual spec
  4. Confirm the main orifice size meets spec and is clean
  5. Check and adjust the venturi or air shutter
  6. Remove and clean the manifold tube
  7. Shut the gas off and let the unit cool before taking anything apart, and use a licensed gas technician for pressure and orifice work

Applies to: Napoleon gas fireplaces - direct vent, natural vent and vent-free (general service manual)

More gas fireplace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 1-3 Troubleshooting, Main Burner Low Flame Flowcharts, p.6 / p.15 / p.24. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.