Napoleon · Gas fireplace troubleshooting
Main burner goes out during operation
What is going on
Main burner shuts off while running. Note flame behaviour first: goes out with no change, goes ghostly blue first, or shrinks after lighting.
Likely causes
- Pilot not covering thermopile/thermocouple
- Dirty/loose electrical connections
- Pressure drop on activation
- Switch/thermostat wire too long or coiled
- Low thermopile output
- Bad operator coil
- Non-millivolt switch/thermostat or unapproved remote
- Venting problem (ghostly blue flame)
- Spill switch tripping / poor draft (natural vent)
Check in this order
- Goes out with no flame change check the pilot covers the thermopile and thermocouple.
- Clean, tighten or replace connections on thermopile, switch, remote and thermostat.
- Goes ghostly blue before going out treat as a vent problem (see Complete Unit Shutdown guide).
- Shrinks shortly after lighting check for pressure drop on activation.
- Check switch/thermostat wire length and gauge are within listed maximums and the wire is not coiled.
- Test thermopile millivolts and the operator coil resistance.
- Use only a millivolt wall switch, a millivolt wall thermostat, or a Wolf Steel approved remote (Advantage/Skytech); replace anything else.
- Natural vent test the spill switch and confirm the unit is drafting and not spilling.
Applies to: Napoleon direct-vent and natural-vent gas fireplaces (general service manual)
More gas fireplace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 1-3 Troubleshooting, Main Burner Failure Flowcharts, p.7 / p.16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.