Napoleon · Gas fireplace troubleshooting
Main burner flame is blue, lazy and transparent
What is going on
A lazy, ghostly blue, see-through flame on the GD70 STARfire is a burner that isn't getting enough combustion air, or one that is breathing its own exhaust. That is a venting problem until proven otherwise. Treat it seriously because poor combustion makes carbon monoxide. The causes are usually outside the fireplace, at the terminal or somewhere in the pipe run.
Likely causes
- Blocked vent or terminal, including ice on the terminal in very cold weather
- Incorrect vent installation, with storm collars in the wrong place
- Flue gases recirculating back into the intake
- Damaged or disconnected vent section
Check in this order
- Shut the unit down until the vent is cleared, because a ghostly blue flame means poor venting
- Inspect the vent and termination and remove any blockage, nests and debris are common
- In very cold weather check for ice on the terminal and remove it as needed
- Check storm collar location against the installation manual diagram (Figure 13) because a collar in the wrong place can cause recirculation
- Check vent joints and seals for gaps or separation
- Relight and look at the flame, it should be more yellow and lively once the venting is right
- If the flame is still wrong, have a licensed gas technician check the installation
Applies to: Napoleon GD70 STARfire direct-vent fireplace (GD70NT-S natural gas, GD70PT-S propane)
More gas fireplace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Napoleon GD70NT-S / GD70PT-S Installation & Operating Instructions W415-0434, Troubleshooting table, p.25. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.