Weil-McLain · Boiler troubleshooting
Zone valve zoning, high-flow or high-head DHW circuit (alternate)
What is going on
Used when the DHW circuit flow rate is higher than the boiler allows, or when a coil-type DHW tank has high pressure drop. Only the DHW water flows through the secondary connection piping.
Check in this order
- Size the secondary connection piping (Figure 15, item 23) for the total flow it must carry.
- Install a system circulator sized for the required flow and head.
- Install a flow/check valve on the boiler outlet piping.
- Keep the boiler loop piping at least the minimum size from Figure 11, page 16.
Applies to: SVF 1500-3000 Series 1
More boiler guides
- 0-10 VDC output for controlling another heat source (P16 pins 1 and 2)
- 0-10 VDC remote modulation input
- 0-10VDC output for lead/lag and variable speed pump
- 120 VAC power supply connection to terminal strip T1
- A sensor is missing from the list at power-up
- Access and clean exchanger, Ultra-155, -230, -299 and -399
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: SVF Series 1 boiler manual, p. 18. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.