Venting general guidelines
What is going on
Direct vent or non-direct vent (room air) are both allowed. Non-direct vent must use Category IV vent of a type listed by a recognised testing agency. Exhaust must always go straight outside. Keep the vent as direct as possible with few fittings, press manufactured joints fully together for an airtight seal, and use only approved sealant, primer or glue. Support horizontal runs about every 4 ft and vertical runs about every 6 ft, or per vent maker or local code. Avoid sags. Reused venting must be inspected and any damaged parts replaced before operation. Do not use cellular core PVC/CPVC, Radel, ABS or galvanised pipe. Do not insulate non-metal vent pipe. Do not mix vent components from different manufacturers. Do not reduce the vent below 2 in. diameter. Do not connect to an existing vent or chimney, and do not common vent with another appliance. Warranty does not cover vent installation problems.
Check in this order
- Confirm the venting option (direct or non-direct) and the vent material is approved for this boiler.
- Keep runs short and direct, with a minimum of fittings.
- Support horizontal runs every 4 ft and vertical runs every 6 ft, or per manufacturer or code.
- Replace any damaged vent components before operating the boiler.
- Do not use cellular core PVC/CPVC, Radel, ABS, galvanised pipe or insulation on non-metal vent.
- Do not mix manufacturers, reduce diameter below 2 in., or connect to an existing chimney.
Applies to: All I-Series Plus venting
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 26. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.