Rinnai · Boiler troubleshooting

Room air combustion air vent installation

I-Series Plus

What is going on

Installs the combustion air vent pipe and vent screen when the boiler draws room air. A room air screen is available as an accessory for dusty rooms.

Check in this order

  1. Remove and discard the screw from the combustion air vent connection.
  2. Remove and discard the combustion air vent cap.
  3. Fit the combustion air vent pipe fully into the connection and secure it with the supplied screw.
  4. Place the 2 in vent screen inside the elbow and secure it with the supplied screw. Use the room air screen instead where the room air is dusty.
  5. Fit the exhaust vent pipe fully onto the exhaust adapter ring and secure it with the supplied screw.

Applies to: Room air (non-direct) venting installations

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Rinnai I-Series Plus IP060160C installation manual, p. 44. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.