Residential garage installation precautions

ECO Tec Series 3

What is going on

Special requirements when the boiler is installed in a residential garage.

Check in this order

  1. Mount the boiler so the burner and igniter are at least 18 inches above the floor.
  2. Locate or protect the boiler so a moving vehicle cannot damage it.
  3. Follow the applicable code (NFPA 54 for US, CSA B149.1 and B149.2 for Canada).
  4. Prevent boiler water and condensate from freezing.

Applies to: Boilers in residential garages

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: ECO Tec Series 3 boiler manual, p. 11. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.