Rapid cycling: boiler turns on and off frequently
What is going on
Boiler short-cycles. Usually a thermostat placement, control setting or water flow problem.
Likely causes
- Thermostat on a wall exposed to drafts or heat sources
- Thermostat heat anticipator set incorrectly
- Limit setting too low (steam boiler)
- Insufficient water flow through boiler
Check in this order
- Move thermostat to an inner wall away from heat sources and drafts
- Adjust thermostat heat anticipator per the thermostat maker's instructions
- On a steam boiler, set the limit to suit the system (maximum 220°F); raise the limit to reduce cycling
- Check all valves to and from the boiler and return them to the proper setting
- Confirm the circulator is correctly sized
Applies to: All listed CGa, CGi, EG, PEG and LGB boilers
More boiler guides
- 0-10 VDC output for controlling another heat source (P16 pins 1 and 2)
- 0-10 VDC remote modulation input
- 0-10VDC output for lead/lag and variable speed pump
- 120 VAC power supply connection to terminal strip T1
- A sensor is missing from the list at power-up
- Access and clean exchanger, Ultra-155, -230, -299 and -399
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Weil-McLain CGa, CGi, EG, PEG & LGB user manual, p. 9. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.