Rinnai · Boiler troubleshooting
Monthly owner maintenance checks
What is going on
Monthly checks for area, piping, venting and boiler condition.
Check in this order
- Confirm the area is free of combustibles, gasoline and flammable vapors, and is clean and unobstructed.
- Confirm the air intake area has no contaminants.
- Inspect water, gas and condensate piping for leaks, corrosion or signs of leaking lines.
- Confirm the condensate line is not blocked; if a condensate pump is used, confirm it works.
- Confirm the vent discharge and air intake are clear, and check vent for leaks, damage or deformation.
- Confirm there are no fault codes, loud noises or leaks on the boiler.
- Confirm the pressure on the controller or external gauge reads 17 to 26 PSI (117 to 180 kPa).
Applies to: I-Series Plus combi boiler
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 115. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.