Monthly condensate drain and trap check

Ultra Series 4

What is going on

With the boiler running, flue gas must not come from the condensate drain or tee. A dry trap lets flue products into the boiler room.

Likely causes

  • Dry condensate trap (not enough condensate from the Ultra vent)
  • Obstructed condensate drain line

Check in this order

  1. While the boiler runs, hold a hand near the discharge end of the condensate drain tubing and the open top of the condensate tee. Check for flue gas escaping.
  2. If flue gas escapes, the trap is dry. Refill the trap using the procedure below.
  3. To check for an obstruction, slowly pour water into the top of the PVC tee on the boiler side. Water should run out the end of the drain line.
  4. If water does not run out, call a qualified service technician to clean or replace the condensate drain line.
  5. To refill the trap, temporarily plug the drain line end. Slowly pour water into the 1/2 inch plastic tee on the boiler right side until it fills the drain line and overflows into the trap tubing.
  6. Stop when water reaches the top of the 1/2 inch tee. Remove the temporary plug from the drain line end.
  7. If the trap keeps running dry, call a qualified service technician to inspect the boiler and condensate line.

Applies to: Ultra Series 4 condensate drain line, condensate tee and trap

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Ultra Series 4 user's information manual, p. 7. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.