Rinnai · Boiler troubleshooting
Hot water works, no central heating
What is going on
DHW is available but there is no space heating.
Likely causes
- CH program key off
- On/off room thermostat sending no call
- RS100 with outdoor sensor: outdoor temperature above the Eco setting (default 70 F)
- Three-way valve not going to CH position
Check in this order
- Switch central heating on.
- Check the room thermostat.
- With RS100, check INFO step 7 and the timer and room temperature settings.
- Check three-way valve wiring; replace the valve motor if needed.
Applies to: E50CRN; E75CRN; E75CRP; E110CRN; E110CRP
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Rinnai E-Combi Series Installation & Servicing Instructions (8U516009 V0116), p.77 (15.4). Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.