Handling ceramic fiber and fiberglass insulation

EG / PEG Series 7

What is going on

Combustion chamber lining, base panels and jacket insulation contain ceramic fiber or fiberglass that can be hazardous if dust is breathed in. Follow these steps when removing or installing these parts.

Check in this order

  1. Avoid breathing dust and avoid contact with skin and eyes.
  2. Wear a NIOSH-certified N95 dust respirator, or a respirator suited to the job site conditions.
  3. Wear long-sleeved loose clothing, gloves and eye protection.
  4. Wet the combustion chamber lining or base insulation with enough water to stop airborne dust.
  5. Remove the lining or base insulation and seal it in a plastic bag for disposal.
  6. Avoid sawing, blowing, tearing out or spraying these materials without extra protection, since they can put fibers in the air.
  7. Wash contaminated clothing separately from other clothing and rinse the washer thoroughly.
  8. First aid for eye contact, irrigate immediately. For breathing problems, move to fresh air.

Applies to: EG and PEG boilers when removing or installing combustion chamber lining, base panels or fiberglass jacket insulation

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: EG / PEG Series 7 Natural Gas-Fired Boiler Manual, p. 91. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.