Weil-McLain · Boiler troubleshooting
Fill the condensate trap and check condensate lines
What is going on
The trap must hold water and have its check float in place whenever the boiler runs. An empty trap lets flue gas out the drain.
Likely causes
- Empty condensate trap.
- Missing check float.
Check in this order
- Inspect the condensate drain line and trap.
- Remove the trap, fill it with fresh water, and reinstall it on the heat exchanger condensate drain.
- Confirm the check float is in place before startup.
Applies to: Condensate trap and drain
More boiler guides
- 0-10 VDC output for controlling another heat source (P16 pins 1 and 2)
- 0-10 VDC remote modulation input
- 0-10VDC output for lead/lag and variable speed pump
- 120 VAC power supply connection to terminal strip T1
- A sensor is missing from the list at power-up
- Access and clean exchanger, Ultra-155, -230, -299 and -399
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: SVF Series 1 boiler manual, p. 87. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.