Weil-McLain · Boiler troubleshooting
Express Setup overview
What is going on
The Wizard is the required method for Express Setup so all required settings are made. Electrical, venting and piping must follow the boiler manual.
Check in this order
- Install boiler and piping per the boiler manual and codes.
- Wire boiler power, inputs/outputs, sensors and multiple-boiler comm cables.
- Turn the manual gas cock off, then turn the boiler on and follow prompts to the Boiler Settings start-up screen.
- Select START WIZARD (or Use App for a ProTools configuration). Do not select SKIP WIZARD unless configuring manually.
- Finish any additional settings for the application.
- Start up the boiler using combustion test instruments per the boiler manual.
Applies to: All Evergreen Series 2 installations
More boiler guides
- 0-10 VDC output for controlling another heat source (P16 pins 1 and 2)
- 0-10 VDC remote modulation input
- 0-10VDC output for lead/lag and variable speed pump
- 120 VAC power supply connection to terminal strip T1
- A sensor is missing from the list at power-up
- Access and clean exchanger, Ultra-155, -230, -299 and -399
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Series 2 Advanced Manual, p. 13. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.