Example B domestic hot water circulator wiring

Evergreen Series 2

What is going on

On the Shadow 4 boiler, the three DHW calls (DHW 1 to 3) are wired with 24 VAC to their own W, R and C terminals. Each DHW circulator runs from its own output rated 2.0 A max with black, white and green leads.

Check in this order

  1. Wire each DHW thermostat call to its W, R and C terminals using 24 VAC.
  2. Wire DHW Circulator 1, 2 and 3 to their own outputs, rated 2.0 A max each.
  3. Check that each DHW circulator load stays within 2.0 A.

Applies to: Example B multi-boiler, DHW wiring on Shadow 4

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Series 2 Condensing Gas Boiler Advanced Manual, p. 25. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.