Electrical supply and wiring requirements

EG / PEG Series 7

What is going on

The boiler ships with controls wired except the spill switch, circulator and vent damper. Wiring must follow NEC Class 1. Always turn off power at the service entrance panel first. Use the wiring diagrams on pages 36 and 37 for the spark-ignited pilot boiler.

Check in this order

  1. Turn off electrical power at the service entrance panel before any connection.
  2. Wire the boiler to NEC Class 1 and ground it per NEC ANSI/NFPA 70.
  3. Connect 120 VAC power through a fused disconnect or service switch; 15 amp is recommended.
  4. If the local code prohibits mounting the switch on the boiler, install a 2 x 4 cover plate on the junction box and mount the switch remotely.
  5. Wire the spill switch, circulator and vent damper, which are not factory wired.
  6. Connect the thermostat per the boiler wiring diagram.
  7. Mount the thermostat on an inside wall away from drafts, hot or cold pipes, lighting, TV, sun and fireplaces.
  8. If using an AcuTemp control, wire it to the boiler control as shown in the diagram.
  9. Connect the DHW aquastat per the wiring diagram; the economy function is not used with DHW input.

Applies to: EG/PEG Series 7 boilers

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: EG/PEG Series 7 boiler manual, p. 31. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.