Weil-McLain · Boiler troubleshooting

Display shows WWSD and boiler stays in standby

Ultra Series 4

What is going on

Warm weather shutdown keeps the boiler from firing when the outdoor temperature is above the WWSD setting. It does not apply to DHW systems and needs the outdoor sensor installed.

Likely causes

  • Outdoor temperature is above the WWSD setting.

Check in this order

  1. Confirm the outdoor sensor is installed and wired to P10.
  2. Check the WWSD setting in the BOILER SETTINGS menu.
  3. Wait for outdoor temperature to drop below the WWSD setting, or adjust the setting if the homeowner needs heat sooner.

Applies to: Ultra U-Control with outdoor sensor

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Weil-McLain Ultra Series 4 boiler manual, p. 99 and p. 104. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.