Weil-McLain · Boiler troubleshooting
Direct exhaust sidewall termination, general rules
What is going on
Installer-supplied termination. Bird screen is not included and must be bought separately. Keep the termination away from anything that can knock it or block it. Never tie another appliance or a second boiler into the same vent pipe.
Check in this order
- Insert a bird screen into the termination elbow before installing it.
- Place the termination where stones, balls, leaves or sediment cannot damage or block it.
- Do not connect any other appliance to the vent pipe.
- Do not connect multiple boilers to one common vent pipe.
- When several boilers vent to the outside, terminate each one separately and space the terminations for service access.
- Seal exterior openings with exterior caulk.
- Do not leave more exposed vent pipe outside the building than the manual shows, because condensate can freeze and block it.
Applies to: Ultra direct exhaust sidewall venting
More boiler guides
- 0-10 VDC output for controlling another heat source (P16 pins 1 and 2)
- 0-10 VDC remote modulation input
- 0-10VDC output for lead/lag and variable speed pump
- 120 VAC power supply connection to terminal strip T1
- A sensor is missing from the list at power-up
- Access and clean exchanger, Ultra-155, -230, -299 and -399
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Weil-McLain Ultra Series 4 boiler manual, p. 88. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.