Dedicated mode recirculation setup and flow

I-Series Plus

What is going on

Used when the plumbing has a dedicated hot water return line. The boiler decides when the pump runs based on time intervals and DHW setpoint.

Check in this order

  1. Confirm the plumbing has a dedicated hot water return line.
  2. Size the pump for the crossover valve and DHW system pressure loss.
  3. Make sure minimum flow is at least 0.5 GPM (2 L/min).
  4. Keep pump current at 2 Amps maximum on the DHW_Pump connection.

Applies to: I-Series Plus Condensing Combi Boiler

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 100. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.