Dedicated mode recirculation setup and flow
What is going on
Used when the plumbing has a dedicated hot water return line. The boiler decides when the pump runs based on time intervals and DHW setpoint.
Check in this order
- Confirm the plumbing has a dedicated hot water return line.
- Size the pump for the crossover valve and DHW system pressure loss.
- Make sure minimum flow is at least 0.5 GPM (2 L/min).
- Keep pump current at 2 Amps maximum on the DHW_Pump connection.
Applies to: I-Series Plus Condensing Combi Boiler
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 100. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.