Decreasing or Fluctuating DHW Water Flow (Combi Only)

I-Series Plus

What is going on

DHW flow volume drops or varies with no code.

Likely causes

  • Gas pressure improper
  • Water pressure improper
  • Dirty DHW inlet filter
  • Lime scale buildup
  • Vent or vent settings wrong
  • Air in the system
  • Recirculation system in use (slight variation is normal)

Check in this order

  1. Confirm gas pressure is proper.
  2. Confirm water pressure is proper.
  3. Clean the DHW inlet filter.
  4. Check for lime scale buildup.
  5. Confirm the vent and vent settings are set up properly.
  6. Purge all air from the system.

Applies to: I-Series Plus combi boiler

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 117. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.