Crossover mode recirculation setup
What is going on
Uses the cold water line for hot water recirculation. Requires a thermal bypass valve at the furthest fixture.
Check in this order
- Install one thermal bypass valve at the furthest fixture in the plumbing system.
- Do not install more than one thermal bypass valve in the system.
- Use only for Crossover mode systems.
- Note that the minimum DHW setpoint becomes 116°F (47°C) in crossover mode.
Applies to: I-Series Plus Condensing Combi Boiler
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 99. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.