Connect the condensate drain pipe
What is going on
Threads the 1/2 in. NPT drain fitting onto the boiler and prepares for the pump safety wiring.
Check in this order
- Apply thread sealant to the 1/2 in. NPT condensate drain port.
- Thread the 1/2 in. NPT fitting on by hand.
- Do not use a wrench on the drain connection, as it can break the joint.
- Wire the condensate pump safety switch if a pump is used.
Applies to: I-Series Plus condensing combi boilers
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Rinnai I-Series Plus IP060160C installation manual, p. 65. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.