Weil-McLain · Boiler troubleshooting
Checking control fuses
What is going on
Check all control fuses before replacing the control or major components such as the blower. A blown fuse can stop the control or other components from running.
Likely causes
- Blown low voltage or line voltage control fuse
Check in this order
- Turn off power to the boiler at the external line switch, then remove the control access door.
- Locate the fuses using Figure 141.
- Remove and inspect all seven fuses (items 1, 2 and 3).
- Replace any faulty fuse only with the specified type from the fuse table. Never jumper a fuse or substitute a different rating.
- Reinstall the control access cover.
Applies to: 80/110/150/199 Series 3
More boiler guides
- 0-10 VDC output for controlling another heat source (P16 pins 1 and 2)
- 0-10 VDC remote modulation input
- 0-10VDC output for lead/lag and variable speed pump
- 120 VAC power supply connection to terminal strip T1
- A sensor is missing from the list at power-up
- Access and clean exchanger, Ultra-155, -230, -299 and -399
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: ECO Tec series 3 boiler manual, p. 160. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.