Carrier · Air handler troubleshooting

Run and cut refrigerant pipe

D5FSAAD5FLAA

What is going on

Cut and prepare the line set carefully to keep the system efficient and reduce future service calls.

Check in this order

  1. Run the interconnecting piping from the outdoor unit to the indoor unit.
  2. Measure the distance between indoor and outdoor units.
  3. Cut the pipe slightly longer than that distance with a pipe cutter.
  4. Make sure the cut is a clean 90 degree angle.
  5. Ream and deburr the cut end, holding the pipe pointing down so burrs fall out. Burrs can break the air-tight seal.
  6. Complete the pipe insulation at the flare connection, then fasten the piping and wiring to the wall and seal the wall hole fully.

Applies to: D5FSAA / D5FLAA air handler, all sizes

More air handler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Carrier D5FSAA/D5FLAA installation manual, p. 24. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.