Indoor unit location requirements
What is going on
Pick an indoor coil location that is firm, has room for service and for the refrigerant and drain piping, and keeps the air inlet and outlet clear. Keep the unit away from moist places, coastal salt air, bathrooms, laundry rooms, oil drilling or fracking areas, strong electromagnetic fields, and any space that stores flammable materials or gas. Keep the indoor and outdoor units, cables and wires at least 1 m (3 ft) from TVs and radios. In a garage, keep heating elements at least 18 in (46 cm) above the floor.
Check in this order
- Confirm the mounting structure can carry the full weight of the indoor unit.
- Check the site is dry, not coastal, and free of corrosive or flammable vapours.
- Leave room for service access and for the connecting pipe and drain.
- Keep the unit at least 1 m (3 ft) from TVs and radios.
- For garage installs, keep heating elements at least 18 in (46 cm) above the floor.
- Ground the indoor unit per national and local electrical code.
Applies to: D5FULA indoor coil installs
More air handler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: D5FULA installation instructions, p. 13. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.