Carrier · Air handler troubleshooting

Electric heat and main circuit wiring notes

D5FUHA

What is going on

Auxiliary electric heater needs its own power supply. Line side of the disconnect in the fan coil stays live when the pull-out is removed.

Check in this order

  1. Do not power the electric heater from the outdoor unit.
  2. Use a separate supply for the auxiliary electric heater and follow the EHKMC installation manual.
  3. Paste the electric aux heat wiring diagram after installing heat modules.
  4. For 208V or 230V connect L1 and L2. For 115V connect L1 and L2 with L2 used as N.

Applies to: D5FUHA indoor unit with auxiliary heat

More air handler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: D5FUHA service manual, p. 13 and 16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.