Carrier · Air handler troubleshooting
Check drain pan opening and install traps
What is going on
Blower-draw units pull air through the coil, so traps are needed to stop air being drawn in through the drain lines.
Check in this order
- After removing the drain pan plug(s), check that each drain hole is fully open and clear of debris.
- Confirm no debris has fallen into the drain pan during installation.
- Install traps in the primary and auxiliary condensate drain lines (if used) on units where the blower draws air through the coil.
Applies to: D5FSAA / D5FLAA air handler
More air handler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Carrier D5FSAA/D5FLAA installation manual, p. 23. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.