Won't start / no cooling

What is going on

Unit won't start and there is no cooling. Work from the outside in: power first, then the controls, then the motor and compressor. Don't open up the compressor until the simple stuff is ruled out.

Likely causes

  • No power at the unit
  • Thermostat failed open
  • Relay failure
  • Start, run or fan capacitor failure
  • Electrical or thermal overload tripped
  • Open, shorted or grounded compressor windings

Check in this order

  1. Test for power at the unit, then the thermostat call, then the relay, capacitors and overloads, in that order, with the disconnect off and locked out whenever you touch wiring
  2. Discharge capacitors before testing them
  3. Ohm out the compressor windings with a meter
  4. Only then consider internal compressor problems
  5. Leave refrigerant circuit work to a licensed technician

More air conditioner guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.