All brands · Air conditioner troubleshooting
Evaporator freezing
What is going on
Evaporator coil freezing up. Ice acts as insulation, airflow drops further, and liquid can flood back to the compressor, so it snowballs. Fix the reason it froze, not just the ice.
Likely causes
- Thermostat set too low
- Low airflow from a dirty filter, bad blower, restricted ducts or closed zone dampers
- Low refrigerant charge
- Effects feed on each other: ice insulates the coil, airflow drops further, liquid floods back to the compressor
Check in this order
- Turn the compressor off and run the blower to defrost. On a heat pump, use heat mode with strips disabled
- Clear the drain first so melt water has somewhere to go
- Check filter, blower and dampers
- Check charge with a licensed tech if airflow is fine
- Correct the cause before restarting cooling
More air conditioner guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.