Hard starting / stalls on restart
What is going on
The unit struggles to start or stalls when you try to restart it right after shutdown. Two common causes: low supply voltage on a PSC motor, or restarting before the system pressures have equalized. Check the voltage before opening any panel, and turn power off before changing parts.
Likely causes
- Low voltage, 10% or more under rating, on a PSC compressor motor
- Restarting before the high and low pressures have equalized
Check in this order
- Confirm supply voltage at the unit while it tries to start, with a meter rated for the voltage and the disconnect on only for the test
- Wait several minutes for pressures to equalize before any restart
- Add a start capacitor and relay as per A1 if the unit still hard starts
- Discharge capacitors and shut off power before installing parts
- If voltage is low, have the utility or an electrician check the supply
More air conditioner guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.