Water dripping inside
What is going on
Water dripping inside from a window or room AC. Usually it's the install, not the unit. Condensate should drain out the back. If it can't, it comes inside.
Likely causes
- Unit not sloped 1/4 inch toward the outside
- Drain hole plugged
- Poor sealing around the unit letting in humid air
- Dirty coil or filter causing icing, then melt
Check in this order
- Check slope with a level, the unit should tilt 1/4 inch to the outside.
- Clear the drain hole.
- Reseal gaps around the cabinet and window frame.
- Clean the filter and coil in case ice is melting.
- Run it and watch for drips.
More air conditioner guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.