Starved evaporator (partial frost, poor cooling)
What is going on
Possible causes and checks for: starved evaporator (partial frost, poor cooling).
Likely causes
- Low charge (leak)
- Partially clogged cap tube/drier
- Undersized cap tube
Check in this order
- Low side low, evap outlet warm, high side low = shortage → find leak. Restriction: head very high + suction into vacuum
- Frosted drier
- Nitrogen flow test to isolate drier vs cap tube
More air conditioner guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.