All brands · Air conditioner troubleshooting

Runs briefly then shuts down, very high head

What is going on

Unit starts, runs a short while and quits with very high head. The compressor internal overload is tripping on heat, Scenario 32F. Find out why it can't reject heat before you reset it again.

Likely causes

  • Dirty condenser coil with leaves or grass
  • Overcharge
  • Failed compressor or fan motor
  • Bent fan blade or poor airflow
  • Recirculating hot air from a blocked enclosure

Check in this order

  1. Check the condenser split, it will be high.
  2. The compressor trips its internal overload and will not restart until cool.
  3. Clean the coil and clear debris.
  4. Trim vegetation back for clear airflow.
  5. Check the fan motor and blade.
  6. Compare charge to the nameplate and have a licensed tech recover any excess.
  7. Caution, the discharge line is very hot, don't grab it.

More air conditioner guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.