Outdoor unit won't start, 24 V present at contactor coil
What is going on
Outdoor unit won't start even though 24 V is present at the contactor coil. If the coil is getting its voltage and the contactor still doesn't pull in, the coil is the suspect.
Likely causes
- Contactor coil open, infinite ohms
- Also check fuses, breakers and the thermostat, since those can look the same
Check in this order
- Confirm 24 V at the coil terminals with a meter
- Turn off the disconnect and ohm the coil, infinite ohms means open
- Check fuses and breakers on the line side
- Verify the thermostat is calling
- Replace the contactor, scenario 32C
More air conditioner guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.