Not cooling
What is going on
The usual culprit on a central AC that runs but never cools is a filthy filter or a frozen coil, so I look there before anything else. If the outdoor unit isn't running at all, the problem is electrical, most often a capacitor or a contactor. Low charge is real but it is a leak, not a refill. Don't add refrigerant until the airflow and electrical sides check out.
Likely causes
- Dirty filter or evaporator coil restricting airflow
- Dirty condenser coil, which raises head pressure and cuts capacity
- Failed capacitor or contactor, a very common reason the outdoor unit won't start
- Low refrigerant charge or a leak
- Tripped breaker or disconnect
- Frozen evaporator coil from low airflow or low charge
Check in this order
- Confirm thermostat is in Cool and set below room temperature
- Replace the filter and check the indoor blower runs
- Check that the outdoor unit runs breaker, disconnect, contactor, capacitor (shut power off at the disconnect before touching anything)
- Clean the condenser coil with a hose from the inside out
- Measure supply and return temperature split, a healthy system is usually in the high teens in degrees F
- If the coil is frozen, shut down to thaw before checking charge
- Check superheat and subcooling against the manufacturer's charging chart, refrigerant work needs a licensed tech
Applies to: Central air conditioners
More air conditioner guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.