All brands · Air conditioner troubleshooting

No cooling, system running, house 81°F at 72°F set, high temp split, low suction, ice on coil

What is going on

The house is 81°F with the thermostat at 72°F, the system is running and the coil is icing. That points to low airflow across the evaporator, not a refrigerant problem, and a big temperature split plus low suction backs it up. Thaw the coil first. Scenario 32B.

Likely causes

  • Dirty filter
  • Dirty evaporator coil
  • Failed indoor blower
  • Undersized ducts causing low airflow

Check in this order

  1. Install a new filter
  2. Thaw the coil completely, with the blower running and the compressor off
  3. Clean the evaporator coil
  4. Check the blower motor and capacitor
  5. Recheck the temperature split, which should be 16–20°F

More air conditioner guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.