Carrier · Air conditioner troubleshooting

Hissing from the outdoor unit after it shuts off

What is going on

If you hear a hiss at the outdoor unit right after it shuts off, relax, it is probably nothing. On the Carrier Infinity 19VS (24VNA9), the pressure equalizer valve opens when the compressor stops and lets the high and low sides balance across the rotary compressor. That makes the next start easier. The sound fades by itself in a short time. A hiss that does not go away, or one that comes with poor cooling, is a different story and needs a proper look.

Likely causes

  • Normal pressure equalizer valve operation during the off cycle
  • Customer unfamiliar with the sound of the variable speed unit
  • A refrigerant leak, if the hiss is constant while running
  • System low on capacity or icing, which would point to a leak and not the valve

Check in this order

  1. Confirm the hiss happens right after the compressor stops and fades away on its own
  2. Explain to the homeowner that this is a normal sound for this unit, to avoid a callback
  3. Listen at the outdoor unit when the system is running, a constant hiss while the compressor runs is not the equalizer valve
  4. If the hiss is constant, or the system has low capacity or icing, check for a refrigerant leak and check pressures instead
  5. Refrigerant leak repair and charging must be done by a licensed technician

Applies to: Carrier Infinity 19VS variable speed air conditioner 24VNA9

More air conditioner guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Carrier Infinity 19VS Variable Speed Air Conditioner 24VNA9 Application Guideline, catalog 24VNA9---01AG (05/16), Sound section, p.5. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.