Viessmann · Boiler
F.59 Supply voltage too low, burner locked out
What the control is telling you
Burner locked out because of low supply voltage.
Applies to: Vitodens 200-W B2HE 85, 120, 150, 199
Likely causes
- Low mains voltage
- Faulty fan unit
Test and repair steps
- Check the mains voltage.
- If voltage is correct and the fault repeats, replace the fan unit.
Models that show this code
4 models in Vitodens 200-W B2HE
Other codes on the same units
- F.549 HC4 mixed supply sensor short circuit
- F.57 Room temperature sensor open circuit
- F.574 HC1 room sensor not available
- F.58 Room temperature sensor short circuit
- F.62 High limit safety cut-out tripped
- F.63 Flue gas temperature limiter tripped
- F.666 DHW preheating sensor TS3 open circuit
- F.667 DHW preheating sensor TS3 short circuit
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Viessmann Vitodens 200-W B2HE 85/120/150/199 Service Instructions 6167 813-24 (09/2026), Fault messages, p.62-73. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.