Rinnai · Tankless water heater

SS (55) Code SS (55)

Menu / mode display SENSEINon-SENSEI

What the display is showing

Listed in the manual index. The section starts on page 58, outside this extract.

Applies to: SENSEI Series and Non-SENSEI Series

Settings for these units

RSC supply connection sizes · SENSEI

ConnectionSize
Gas3/4 in. NPT
Cold inlet3/4 in. NPT
Hot outlet3/4 in. NPT
Condensate drain1/2 in. NPT
Pressure relief valveM33 thread

The PRV and its adapter come in the box; PRV must be rated 150 psi and at least the heater Btu/h.

Condensate drain line must stay at least 1/2 in. over its whole length.

RSC water quality limits · SENSEI

ContaminantMaximum level
Total hardnessUp to 200 mg/L
AluminumUp to 0.2 mg/L
ChloridesUp to 250 mg/L
CopperUp to 1.0 mg/L
Dissolved CO2Up to 15.0 mg/L
IronUp to 0.3 mg/L
ManganeseUp to 0.05 mg/L
pH6.5 to 8.5
TDSUp to 500 mg/L
ZincUp to 5 mg/L

Damage from water above these limits is not covered by warranty.

Hard water should be treated; use the Service Soon (SS) reminder (parameter 03) for flushing intervals.

Models that show this code

78 models in SENSEI, Non-SENSEI

C199eC199iCU160eCU160iCU199eCU199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRSC160eRSC160iRSC199eRSC199iRU130eRU130iRU160eRU160iRU180eRU180iRU199eRU199iRU80eRU80iRU90eRU98eRU98iRUC80iRUC90iRUC98iRUCS65i

Other codes on the same units

  • Perf data Performance data viewer (live readings and counters)
  • Priority light Priority light on (this controller is in charge)
  • S Venturi reset sequence: step S (SENSEI)
  • SE Cascade diagnostic display (error on secondary unit)
  • SS Service Soon alert (also listed as 55)
  • Water flow fault (no code displayed) No-code water flow fault
  • t Venturi reset sequence: step t
  • °C/°F Temperature scale switch (Celsius / Fahrenheit)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Troubleshooting Tankless Water Heater Diagnostic Codes, p. 1. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.