Rinnai · Tankless water heater
Parameter settings Parameter (installer settings) mode
What the display is showing
Lets the installer change numbered settings such as maximum temperature, recirculation, pump speed and Service Soon interval.
Applies to: SENSEI RX/CX (RX199i, RX180i, RX160i, RX130i, CX199i, CX160i, RXP199i, RXP160i, CXP199i, CXP160i)
What to do
- Press the A button on the PC board for 1 second to enter.
- Use the controller up/down arrows to choose the setting number.
- Press On/Off on the controller to step through the option letters (for example 01A to 01b).
- Press the A button on the PC board for 1 second to exit.
Settings for these units
RX supply connection sizes · SENSEI RX/CX
| Connection | Size |
|---|---|
| Gas | 3/4 in. MNPT |
| Cold inlet | 3/4 in. MNPT |
| Hot outlet | 3/4 in. MNPT |
| Condensate drain | 1/2 in. MNPT |
Vent connection: 2 in. nominal PVC/CPVC/PP or 3 in./5 in. concentric.
Full specs (input, flow, weight) are only on each model's spec sheet, not in this manual.
RX water quality limits · SENSEI RX/CX
| Contaminant | Maximum level |
|---|---|
| Total hardness | Up to 200 mg/L |
| Aluminum | Up to 0.2 mg/L |
| Chlorides | Up to 250 mg/L |
| Copper | Up to 1.0 mg/L |
| Dissolved CO2 | Up to 15.0 mg/L |
| Iron | Up to 0.3 mg/L |
| Manganese | Up to 0.05 mg/L |
| pH | 6.5 to 8.5 |
| TDS | Up to 500 mg/L |
| Zinc | Up to 5 mg/L |
Water damage beyond these limits is not covered by warranty.
- RX water treatment and flushing by hardness · SENSEI RX/CX
- RX clearances to combustibles · SENSEI RX/CX
- RX temperature settings available · SENSEI RX/CX
Models that show this code
10 models in SENSEI RX/CX
Other codes on the same units
- Lock key Controller locked (key symbol)
- Mute Controller key beeps on/off
- Out Initial setting: outdoor installation
- Parameter mode Parameter settings menu
- Perf data Performance data viewer (live readings and counters)
- Performance data Performance data readout mode
- Priority light Priority light on (this controller is in charge)
- SE Cascade diagnostic display (error on secondary unit)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Rinnai SENSEI RX/CX technical guide U362-0875, service procedures. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.