Rinnai · Tankless water heater
Out Initial setting: outdoor installation
What the display is showing
Shown on the controller of RX/CX units during first-time setup when outdoor is selected (for installs with the Versa-Vent outdoor vent cap). Confirming it stores the outdoor setting; it can also be changed later with parameter 14.
Applies to: Rinnai SENSEI RX/CX tankless (RX, RXP, CX, CXP)
What to do
- From the In screen press Up or Down Out appears.
- Press On/Off to confirm outdoor.
Settings for these units
RX supply connection sizes · SENSEI RX/CX
| Connection | Size |
|---|---|
| Gas | 3/4 in. MNPT |
| Cold inlet | 3/4 in. MNPT |
| Hot outlet | 3/4 in. MNPT |
| Condensate drain | 1/2 in. MNPT |
Vent connection: 2 in. nominal PVC/CPVC/PP or 3 in./5 in. concentric.
Full specs (input, flow, weight) are only on each model's spec sheet, not in this manual.
RX water quality limits · SENSEI RX/CX
| Contaminant | Maximum level |
|---|---|
| Total hardness | Up to 200 mg/L |
| Aluminum | Up to 0.2 mg/L |
| Chlorides | Up to 250 mg/L |
| Copper | Up to 1.0 mg/L |
| Dissolved CO2 | Up to 15.0 mg/L |
| Iron | Up to 0.3 mg/L |
| Manganese | Up to 0.05 mg/L |
| pH | 6.5 to 8.5 |
| TDS | Up to 500 mg/L |
| Zinc | Up to 5 mg/L |
Water damage beyond these limits is not covered by warranty.
- RX water treatment and flushing by hardness · SENSEI RX/CX
- RX clearances to combustibles · SENSEI RX/CX
- RX temperature settings available · SENSEI RX/CX
Models that show this code
10 models in SENSEI RX/CX
Other codes on the same units
- LPG Initial setting: propane (LPG)
- Lock key Controller locked (key symbol)
- Mute Controller key beeps on/off
- Parameter mode Parameter settings menu
- Parameter settings Parameter (installer settings) mode
- Perf data Performance data viewer (live readings and counters)
- Performance data Performance data readout mode
- Priority light Priority light on (this controller is in charge)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Rinnai SENSEI RX Residential Installation and Operation Manual (100000839), 4.12 Initial Settings p.46-47. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.