Rheem · Furnace

tr Temperature rise readout (pushbutton status menu)

Menu / mode display R96V/96MDV

What the display is showing

Supply minus return air temperature in F. Only shown when the optional supply air sensor is connected.

Applies to: (-)96VA040-115 (R96V / U96V) and (-)(-)96MDV040-115 two-stage variable-speed communicating furnaces

What to do

  1. Step the pushbutton until tr shows while the furnace runs on gas heat; compare with the rise range on the rating plate.

Settings for these units

Models that show this code

1 model in R96V/96MDV

96MDV115D50A

Other codes on the same units

  • FL Fault history (pushbutton status menu)
  • Fr Fire rate readout (pushbutton status menu)
  • H Gas heat on
  • HP Heat-pump heat running (dual fuel)
  • UI Unit input readout (pushbutton status menu)
  • cd / Cd Dehumidification cooling
  • dF Defrost in progress (dual fuel)
  • h (lowercase) Low-fire gas heat on

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rheem (-)96V / (-)(-)96MDV Installation Instructions 92-24161-124-08, 15 Pushbutton (S8) p.95-96. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.